BUSINESS FIELD
BUSINESS FIELD

Cryogenic control valves

The cryogenic control valve is a high-performance control valve used in LNG carriers, cryogenic tankers, and more. It boasts excellent operability in environments with super-low temperatures and excellent tightness that meets ANSI Class V.

Features

Leak-tightness
Proportional Flow Characteristics for Precision Control
Optimized design for durability

Specifications

Pressure Drop 1~3 Stage
Size ¼”~20”
Pressure ANSI Class #150~#2500
Temperature -196 ~ 60℃
Body Type Globe, Angle, 3-way
Leakage ANSI Class V, no leak
Connection RF, BW
Material Stainless Steel

Seat Leakage Class for Control valve (ANSI/FCI 70.2)

Leakage Class Maximum seat leakage Testing fluid and pressure
Class I Level mutually agreed upon by the user and supplier None
Class II 0.5% of valve rated capacity Air or Water (3.5 kg/㎠)
Class III 0.1% of valve rated capacity Air or Water (3.5 kg/㎠)
Class IV 0.01% of valve rated capacity/td> Air or Water (3.5 kg/㎠)
Class V 5×10-13㎥/s level Water (maximum operating pressure)
Class VI Defined in a separate table Air or nitrogen (3.5 kg/㎠ or maximum operating pressure below this pressure)

Flow control via plug

Linear Flow Characteristic

Applied valve
Liquid Level Control
Flow Control within a certain range
Flow is proportional to the valve plug travel
When the flow travels 50%, the flow rate is 50%.
When the flow travels 80%, the flow rate is 80%.
Valve in use
D/A Level Control Valve

Equal Percentage Characteristic

When the valve plug travel changes(%), the flow shows the same change(%) from the current flow.
When the flow travels 18%, the flow rate is 50%.
When the flow travels 50%, the flow rate is 80%.
Applied valve
Pressure Control
When the Pressure Drop is large
Valve in use
BLCV

Modified Parabolic

Between linear and equal percentage
It operates similarly with sophisticated throttling at low flows and linear at high flows.

Quick Open Characteristic

Valves that need to be opened quickly
When the flow travels 80%, the flow rate is 50%.
When the flow travels 95%, the flow rate is 80%.
Applied valve
Relief Valve